Permit: T03CM01582

Parcel: 13613001P

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/14/2003 PLUMBING - FINAL Approved SLONG APPROVED GREASE TRAP ONLY, TRINI VALENCIA IS APPROVING ALL OTHER PLUMBING FINAL ITEMS
07/09/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*/1) GREASE TRAP MUST BE CONNECTED DIRECTLY TO SANITARY SYSTEM. INDIRECT WASTE IS FOR FOOD PREP FIXTURES ONLY, SEE SEC. 304.0 94UPC. 2) CAN NOT HAVE FENCE COUPLINGS WITHIN THE STRUCTURE. 3) CAN NOT USE NO HSB COUPLING ON PVC TO GREASE TRAP OUTLET. SPECIALTY COUPLING REQUIRED. 4) MUST USE DIRECTIONAL FITTINGS FOR ALL CONTINUOUS WASTE, SEE SEC. 405.4 94 UPC. 5) MENS WATER CLOSET MUST BE ELONGATED W/ OPEN FRONT SEAT 6) WOMENS H.C. LAVATORY DOES NOT MEET ADA STANDARDS. 7) COFFEE MACHINE REQUIRES A BACKFLOW PREVENTER. 8) ALL BACKFLOW PREVENTORS IN HOUSEE MUST BE TESTED & CERTIFIED PRIOR TO FINAL INSPECTION. 9) GREASE TRAP REQUIRES PROPER CLEARANCE FROM CONT. WASTE TO BE ABLE TO CLEAN TRAP. 10) WATER HTR. REQUIRES A DRIP PAN & DRAIN SEE SEC. 510.7 94 UPC. 11) INTERMEDIATE AND ABOVE CEILING HAS NOT BEEN APPROVED. CLOSET RING NOT SEEN AS REQUESTED.