Permit: T03CM01524

Parcel: 120072010


Addresses:

161 W PALMDALE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/10/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*LEFT GAS CARD.
04/09/2003 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*
PRESSURE TEST IS OK
2.) DOUBLE WALL VENT PIPE ON WATER HEATER IS INSTALLED UPSIDE DOWN.
3.) PROVIDE VACUUM BREAKERS ON NEW HOSE BIB.
4.) PROVIDE SCREWS IN WATER HEATER VENT CONNECTORS.
04/07/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999*
1.) RETEST SYSTEM T0 10#.
2.) PETITION OF APPEAL MUST BE LEFT ON JOBSITE.
3.) UNTAPE CONNECTION BETWEEN VENT CONNECTOR AND VENT
4.) PAN TO BE NON COMBUSTIBLE MAT'L.
5.) SCREW (3) CONNECTION BETWEEN APPLIANCE CONNECTOR AND VENT CONNECTOR.
6.) ALL HOSE BIBBS TO HAVE ATMOSPHERE VACUUM BREAKERS. 161 W. PALMDALE PETITION OF APPEAL
03/27/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*CAP OFF VALVES IN KITCHEN WALL HEATER IS OK
PROVIDE 1" CLEARANCE AROUND VENT. PROVIDE ROOF JACK. SYSTEM NOT HOLDING PRESSURE.