Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM01517

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM01517

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/04/2003 FRAMING Approved IVRS - Inspection 0000*
06/02/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) FRAMING AT KITCHEN CORNER, NEEDS WOOD AT LOWER CORNER 2) STRAP PEX REAR BEDROOM HOSE BIB 3) BANG PLATES AT WATER SERVICE LINE 4) INSULATE DISTRIBUTION BOX HALL WALL 5) SUPPORT DIVERTER VALVE 6) STRAP AT WATER SERVICE 7) GAS PRESSURE, DWV AND WATER-OK
05/28/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SECURE STRIKER OUTLET 2) SHEETROCK SHEAR BLOCKS AT TOP OF GARAGE WALL 1/2" LIP NO NAILING SURFACE LEFT FOR WALL 3) REAR LAV OVER TRAP ARM LENGTH AND WRONG SIZE PIPE STOPPED INSPECTION PLUMBING ISN'T FINISHED 4) BLOCK ALL MECHANICAL VENTS USING GAS DEMAND TABLE ON YOUR PLAN PIPE IS TO SMALL