Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 07/31/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 07/30/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) A TRAP ARM AND TRAP TO BE THE SAME SIZE 2) SURFACE CLEANOUTS REQUIRE COVER 3) A WOOD SCREW TAPPED INTO ABS PLUG NOT APPROVED. USE COUNTER SINK TAPPED CLEANOUT PLUG WITH APPROVED SCREW |
| 07/29/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL STAND-OFFS AT WATER SOFTNER DRAINS. 2) PROVIDE INSTALLATION SHEET FOR AIR ADMITANCE VALVES (SHOWING HORIZONTAL INSTALLATION) 3) INSTALL SET SCREW AT BACKFLOW ON SOUTH/WEST |