Permit: T03CM01514

Parcel: 116182870

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Permit Number - T03CM01514

Inspection Description - PLUMBING - SEWER HCS CONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
07/09/2003 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection 0000*/ 1) BLDG SEWER FROM Z WAY C.O. TO HCS CONNECTION - OK. 2) DON'T FORGET TO ADD CHANGE OF DIRECTION CLEAN-OUT AT TEST WYE. I WILL CHECK THIS ON FINAL. 3) OK TO BACKFILL.
07/07/2003 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection 0999*1) PIPING TO BE LAID ON A FIRM BED. NO BRIDGING 2) PIPE SHALL HAVE UNIFORM SLOPE OF 2% TOWAWRD SEWER MAIN. NO BACK PITCH. 3) ADDITIONAL CLEAN OUT REQUIRED AT AGGERGATE CHANGE OF DIRECTION.