Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T03CM01514
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2003 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*/ 1) BLDG SEWER FROM Z WAY C.O. TO HCS CONNECTION - OK. 2) DON'T FORGET TO ADD CHANGE OF DIRECTION CLEAN-OUT AT TEST WYE. I WILL CHECK THIS ON FINAL. 3) OK TO BACKFILL. | |
07/07/2003 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*1) PIPING TO BE LAID ON A FIRM BED. NO BRIDGING 2) PIPE SHALL HAVE UNIFORM SLOPE OF 2% TOWAWRD SEWER MAIN. NO BACK PITCH. 3) ADDITIONAL CLEAN OUT REQUIRED AT AGGERGATE CHANGE OF DIRECTION. |