Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM01514
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* 1.) ABS DWV THRU ROOF OK 2.) PEX PIPE OK 3.) CLOSET FLANGES OK 4.) TUBS OK 5.) OK TO COVER WALLS. |
|
05/15/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) WATER TEST ABS THRU ROOF. 2.) MAY DIRECTLY CONNECT SOFTENER DRAIN TO SANITARY SEWER VENT. 3.) SUPPORT HORIZONTAL ABS. 4.) PRESSURE TEST PEX. 5.) REQUIRE FULL SIZE CLEAN OUT AT END OF LINE. 6.) PROVIDE FIRE STOPPING FOR DEMISING WALL MEMBRANE PENTRATION. |