Permit: T03CM01507

Parcel: 125090630


Addresses:

2815 E POMPEII CI

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/12/2003 FRAMING Approved IVRS - Inspection 0000*
12/11/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) OK TO DRY WALL EXCEPT FOR FUR DOWNS AT LAUNDRY/FIRE BLOCK MISSING
12/10/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) MOVE PEX FROM CAN IN MASTER TOILET, ABOVE HALL TUB AND #1 BED CLOSET 2) BANG PLATE ABS IN MASTER SHOWER 3) BLOCK MASTER BED DUCT BOOT 4) GROUT HALL TUB 5) CORRECT NEGATIVE PITCH AT HALL LAV ARM
12/09/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) COMPLETE ALL TRADES AND THEN CALL FOR INSPECTION