Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM01499
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
06/06/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) A.B. WEST WALL 2) PIPE OUT OF WALL 3) SECURE WATER SERVICE LINES 4) USE CORRECT NAILS AT H.D. KITCHEN WALL 5) SHEAR TRANSFER BLOCKS VAULTED CEILING LEAVE ENOUGH TO NAIL WALL 6) FIREBLOCK STAIR STRINGER 7) LIGHT CAN GARAGE HALL MOVE 12" AWAY FROM PEX 8) SECURE PEX AT WASHER TRAY 9) SHIM ALL GARAGE TRUSSES 3 PT BEARING 10) BANG PLATE ALL ABS, 2" SHOWER VENT OUT OF WALL 11) ADJUST DAMPERS 12) 2ND FLOOR PEX AT TUB SECURE 13) PACK INSULATION AT LINE SETS, WATER HEATER FLUE 14) SPACER AND NAIL TRANSFER LIVING KITCHEN WALL |