Permit: T03CM01489

Parcel: 13317062A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM01489

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/10/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000* 1) CORRECTIONS HAVE BEEN MADE ON UNDERFROND NEED TO INSTALL TWO CO. 2) DEVELOPER WILL REQUIRE A BACK FLOW DEVICE " R P DEVICE" FOR WTER SUPPLY. 3) PLEASE PROVIDE APPROVED RECPTOR FOR BACK FLOW DEVICE SEE 94 UPC DEFINITION. ALSO SEE PLUMBING FIXTURES DEFINITIONS. 4) WHEN CALLING FOR INTERMEDIATE VENT SHAL RISE 6" ABOVE FLOOD LEVEL OF SINK.
06/01/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999* 1) USE SOVENT WELD COUPLING ON ABA X ABS 2) REQUIRED TYPE " K TYPE COPPER UNDER SLAB 3) REQUIRED FULL SIZE CLEAN OUT BEHING WATER CLOSET PLAN SHOWS 3" VTR 4) ALL NEW PIPING TO BE WATER TESTED TO A MINIMUN OF TEN FEET. 5) HAVE PLUMBER CHECK ALL WORK BEFORE CALLING INSPECTIONS/ THIS DEPARTMENT DOES NOT PROVIDE PUNCHLISTS.