Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM01489
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2003 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* 1) CORRECTIONS HAVE BEEN MADE ON UNDERFROND NEED TO INSTALL TWO CO. 2) DEVELOPER WILL REQUIRE A BACK FLOW DEVICE " R P DEVICE" FOR WTER SUPPLY. 3) PLEASE PROVIDE APPROVED RECPTOR FOR BACK FLOW DEVICE SEE 94 UPC DEFINITION. ALSO SEE PLUMBING FIXTURES DEFINITIONS. 4) WHEN CALLING FOR INTERMEDIATE VENT SHAL RISE 6" ABOVE FLOOD LEVEL OF SINK. | |
| 06/01/2003 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999* 1) USE SOVENT WELD COUPLING ON ABA X ABS 2) REQUIRED TYPE " K TYPE COPPER UNDER SLAB 3) REQUIRED FULL SIZE CLEAN OUT BEHING WATER CLOSET PLAN SHOWS 3" VTR 4) ALL NEW PIPING TO BE WATER TESTED TO A MINIMUN OF TEN FEET. 5) HAVE PLUMBER CHECK ALL WORK BEFORE CALLING INSPECTIONS/ THIS DEPARTMENT DOES NOT PROVIDE PUNCHLISTS. |