Permit: T03CM01478

Parcel: 140321250

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/19/2003 FRAMING Approved IVRS - Inspection 0000*
05/15/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) PROVIDE ENGINEERING FOR FLOOR TRUSS WEST WALL FIRST FLOOR AND REPAIR DOUBLE TOP PLATE KITCHEN SHEARWALL 2) OK TO START SHEET ROCK LEAVE TWO ? OPEN FOR INSPECTION 3) HOOD VENT NEEDS TO BE INSTALLED AFTER REPAIR
05/09/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) FLOOR TRUSS OVER NOTHED WEST WALL, REQUIRES ENGINEERING 2) BLOCK RETRUNS 2ND FLOOR HALL AND MASTER BEDROOM 3) FURNACE FLU REQUIRED MINIMUM 1" CLEANANCE FROM COMBUSTIBLES 4) DETAIL 13/D6 DOUBLE TOP PLATE CUT 12" NEED APPROVED REPAIR 5) COMPLY WITH DETAIL 4/D7