Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01467
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
09/11/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) COIL STRAP MUST HIT FRAMING ABOVE AND BELOW FLOOR FRAMING 2) SHEAR TRANSFER AT STAIRWLL REQUIRES 6" ON CENTER NAILING 3) TOP PLATES REQUIRE MINIMUM 2' LAP OR STRAP |