Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 06/03/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) HEAT PUMP NOT IN-NEW BEDROOM OK EXCEPT FOR HEAT PUMP 2) ENTRY REQUIRES STUD BY EXISTING DOOR AND BY NEW DOOR MAXIMUM 16" ON CENTER 3) 1/2" ANCHOR BOLTS REQUIRED IN SILL PLATES WITHIN 12" OF EACH END 4) ENTRY BOTTOM PLATES MUST BE TREATED WOOD 5) ENTRY REQUIRES A MINIMUM OF DOUBLE 2 X 4 HEADER WITH SUPPPORTING TRIMMERS |