Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/21/2003 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection 0000*/1) CORRECTIONS MADE OK. 2)PLUMBING FINAL OK. 3) OK FOR C OF O PENDING ANY OTHER INSPECTION AND VERIFICATION OF CERTIFICATION OF 3/4" RPZ. WATTS 009 # 139570 |
| 08/20/2003 |
PLUMBING - FINAL |
|
Denied |
IVRS - Inspection 0999*/1) ICE BIN AND ICE MAKER MUST BE DRAINED SEPERATLY. MATERIAL TO BE APPROVED TYPE. INDIRECT WASTE PIPING BETWEEN 5'-15' FIXTURE TO BE DIRECTLY TRAPPED. 2) VACUUM BREAKER AT SVAP MACHINE NOT APPROVED. |