Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2003 |
MECHANICAL - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000* |
| 10/20/2003 |
MECHANICAL - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CHECK ALL PEX LINES AT METAL STUDS FOR PROTECTION SHARP EDGES. 2) ALL PEX LINES 12" AWAY FROM CAN LIGHTS. 3) 2' CLEAR AT FIREPLACE FLUE TO COMBUSTABLES INSTALL METAL FIRE STOP AT DROP. 4) HEARTH SAFTY STRIP HALF UNDER. 5) DRYWALL BACKING AT TUB SIDE. 6) RETURN PLENIUM AT WEST FURNACE ROOM? 7) FRONT 3/4 BATH MOVE ABS OFF LIGHT CAN. 8) GARAGE FURNACE, PLENIUM GARAGE. 9) KIT. VENT SINK USE 45 DEGREE FITTINGS OR PUT PROPER PITCH ON VENT 1/4" PER FT. 10) NEED PIPE AS BUILT DIAGRAM FOR GAS LINE WITH SECTION LENGTH, PLAN VIEW HAS NO MEASUREMENTS ON IT. GAS PRESSURE IS HOLDING. 11) NO H2O IN DRAIN WASTE AND VENT. |