Permit: T03CM01438

Parcel: 112043390

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/22/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
12/19/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) VENT 90 DEGREE FITTING NOT ALLOWED TO BE INSTALLED IN SHOWER DRAIN-MUST USE A LONG SWEEP 90 DEGREE BEND FITTING. REPLACE FITTING AND RETEST 2) I COULD NOT LOCATE YOUR PLAN/PERMIT. THEY MUST BE ON SITE FOR INSPECTION
12/10/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) PROVIDE TEST 10' HIGH (WATER) 2) CAP ALL VENTS AND DRAINS EXCEPT FOR ONE-EXTEND 10' 2) AB'S SOIL PLUMBING MUST BE UNDER PRESSURE WHEN INSPECTOR IS ON SITE 3) UNCOVER ALL JOINTS
12/08/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) IMPROPER VENTING AT WATER CLOSET