Inspection Status: Approved
Inspection History: ELECTRIC - UFER
| Date |
Description |
Inspector |
Results |
Comments |
| 02/13/2004 |
ELECTRIC - UFER |
|
Approved |
IVRS - Inspection 0000* |
| 01/30/2004 |
ELECTRIC - UFER |
|
Denied |
IVRS - Inspection 0999*/ 1) INSTALL NAIL PROTECTION ALL ELECTRIC, PLUMBING, ETC... 2) INSTALL POSITIVE CONNECTION PORCH LEDGER TO BEARING 3) NEED APPROVED TRUSS DRAWINGS 4) BACK GROUT PLUMBING UNDER TUBS 5) COMPLETE LATH 6) INSTALL A-35 EACH STUD TO LEDGER. INSTALL ALTERNATE HOLDOWNS CORNER SHEAR WALLS 7) MAKE UP ALL GROUNDS MAIN ELECTRIC PANEL 8) GROUNDING ELECTRODE CONDUCTORS INSTALLED WRONG LOCATION IN PANEL 9) WATER TEST DWV SYSTEM 10) PLATE BOLT NUTS CUT TO DEEP INTO BOTTOM PLATES, INSTALL ALTERNATE ? BOLTS 11) SHEAR WALL NAILS SET TO DEEP-RENAIL 12) STOPPED INSPECTION 13) INSTALL ALL ROOF VENTS 14) INSTALL HOLES ALL RAFTER SPECES FOR VENTILLATION 15) COMPLETE ALL AND RECALL |
| 09/12/2003 |
ELECTRIC - UFER |
|
Not ready for Inspection |
IVRS - Inspection 0000* |