Permit: T03CM01428

Parcel: 122081040

Inspection Status: Approved

Inspection History: MECHANICAL - ABOVE CEILING

Date Description Inspector Results Comments
08/24/2004 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection :*
08/20/2004 MECHANICAL - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/17/2004 MECHANICAL - ABOVE CEILING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) REMOVE SCREEN FROM DRYER VENT T-TOPS 2) PROVIDE FHA STRAPS ON DRYER VENTS 3) PROVIDE BACKIGN AROUND SIDE WALL REGISTER BOXES 4) EXTEND FURNACE VENT AND COMBUSTIBLE VENTS BELOW CEILING IN CLOSET 5) EXTEND KITCHEN EXHAUST BELOW CEILING 6) PROVIDE A FRAMED OPENING FOR THE RETURN AIR 7) PROVIDE SUPPORT ON WATER HEATER VENTS AND FURNACE VENTS 8) PROVIDE INSULATION SHIELDS TO KEEP INSULATION OFF OF 'B' VENTS 9) PROVIDE BACKING AROUND EXHAUST FAN SIN DRYER ROOMS 10) PROVIDE A SUPPLY BOX FOR LIVING ROOM