Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/05/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)WASTE & VENT SYSTEM IS OK 3)OVERHEAD WATER DISTRIBUTION IS OK | |
| 08/26/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/NR-NOT READY FOR INSP. JOB NOT INSTALLED AS PER APPROVED PLAN. PLEASE PROVIDE APPROVED REVISED PLAN ON INSTALL AS PER PLAN ALSO NOT TO SPEC SITE WATER COVERS W/OUT INSP-UNABLE TO MAKE INSP. WITH OUT APPROVED PLAN-DO NOT COVER | |
| 08/24/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/NR 1) LATER LINE COVERED W/OUT INSP-SEE SPEC 2) CODE VIOLATION ON TRAP ARM AT LAUNDRY WASHER TRAP ARM TO SHOWER 3) RELIEF VALVE NOT INSTALLED 4) GAS HOSE NOT INSTALLED AS PER PLAN PLEASE REVIEW PLAN 5) REPAIR KINK? IN WATER VALVE INSIDE 6) STRAP? ARE COPPER INSIDE. MAKE CORRECTIONS AND CALL AGAIN WATER TEST DOWN ON ABS |
|
| 08/17/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/NOT READY-COMPLETE ROUGH SOIL INSPECTION PRIOR OT THESE INSPECTIONS |