Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM01398
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000*/ 1) TRUSS GABLE END BRACING TOO BE 8'-0" ON CENTER USE A HORIZONTAL BLOCK TO ATTACH TO TRUSS CHORD USE NAILS IN SHEAR 2) T-BRACE TRUSS H-2 3) CHECK BLOCKS AT INTERMEDIATE IN GARAGE OSB WITH END EDGE UNSUPPORTED |