Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM01316

Parcel: 138020420


Addresses:

5750 S 14TH AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
02/03/2004 BUILDING - FINAL Approved IVRS - Inspection 0000* SENT 2/4/04 TO TEP
01/27/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) 5750 ADDRESS MUST BE ON HOUSE IN 3" OR LARGER NUMBERS 2) OUTSIDE HOSE BIBS MUST HAVE ANTI-SIPHON VALVES 3) OUTSIDE WALLS AND LIGHTS HAVE BEEN BUILT WITHOUT INSPECTION OF WIRING-EXPOSE 4) OUTSIDE ELECTRIC PLASTIC CONDUIT TO SHALLOW 5) SECURE UFER GROUND TO HOUSE 6) DOUBLE LUGGING OF CIRCUIT BREAKER (WASHER) NOT ALLOWED 7) WHITE WIRES CANNOT BE HOT, COLOR CODE RED 8) WATER HEATER T&P LINE CANNNOT USE CORRIGATED TUBING AND MUST FLOW DOWN. ALSO MUST EXHAUST 6" TO 18" ABOVE GROUND 9) DRYER DUCT NOT IN 10) GARAGE OUTLETS MUST BE GFCI PROTECTED 11) CAP UNUSED GAS LINE 12) HALL BATH OUTLET NOT GFCI AND WIRED WRONG 13) NO COOLING