Permit: T03CM01296

Parcel: 130191290


Addresses:

4601 E 31ST ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/13/2003 FRAMING Approved IVRS - Inspection 0000*
05/12/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) BANG PLATE WIRING WHERE NEEDED FOR PROTECTION 2) SECURE HALL SHOWER SURROUND WEST EDGE AND MASTER SURROUND WEST EDGE 3) BANG PLATE 3" VENT AT HALL BATH TOP PLATE 4) SECURE OVERNOTCHED STUD JUST SOUTH OF 3" VERTICAL PIPE IN HALL BATH 5) INSTALL X BRACE AT MID-SPAN TRUSSES (X'S AT EACH GABLE, 1 X IN MIDDLE) 6) NEED DRAINAGE, WASTE AND VENT (DWV) TEST 7) WATER PRESSURE AND GAS PRESSURE OK-5/12