Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 07/29/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 07/24/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE TEST FOR DWV'S 2) WATER TEST-OK 3) NAIL PROTECT ELECTRICAL WITHIN 1 1/4" FROM EDGE OF STUD 4) NAIL PROTECT ALL PLUMBING WITHIN 1 1/2" FROM EDGE OF STUD 5) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE |