Permit: T03CM01278

Parcel: 10512023A


Addresses:

4120 N ORACLE RD

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
09/23/2003 PLUMBING - YARD WTR LINE/TEST Approved IVRS - Inspection 0000*
07/28/2003 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection 0000*
07/24/2003 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection 1) YOU CAN COVER FROM METER TO BACK FLOW DEVICE ONLY 2) LEAK ON OUT LEFT SIDE PVC 3) PLEASE PROVIDE LISTING ON WYE ? CALL AGAIN
07/23/2003 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection 0999*/ 1) NO PORTION OF ANY WORK MAY BE CONCEALED UNTIL IT HAS BEEN INSPECTED AND APPROVED. EXPOSE ALL PIPE AND EVERY FITTING BETWEEN METER AND RPPBP FOR VISUAL INSPECTION. 2) PLEASE EXPLAIN TO ME HOW A WYE STRAINER INSTALLED ON THE VERTICAL RISER IS SUPPOSED TO WORK.
07/22/2003 PLUMBING - YARD WTR LINE/TEST Denied IVRS - Inspection 0999*/ 1) CONNECTIONS FOR RPPBP, AND ALL PIPING BETWEEN RPPBP, AND METER COVERED BEFORE INSPECTION.
06/24/2003 PLUMBING - YARD WTR LINE/TEST Partial Approval IVRS - Inspection 0000*/ 1) NOT READY FOR INSPECTION 2) 4" ABS SEWER FROM 2 WAY CLEANOUT (2-LOCATIONS) TO TIE IN AT EXISTING OK, WATER TEST OK, OK TO COVER 3) PLUMBING YARDWATER FROM BLDG TO RISER OK, OK TO COVER 4) ABS UNDERGROUND OK, OK TO COVER