Permit: T03CM01247

Parcel: 123052210


Addresses:

2209 N TUCSON BL

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
06/23/2005 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
06/29/2004 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*/ 1) 2" VTR REQUIRED FOR TOILET, VENT THE TRAP ARM NOT THE TRUNK LINE IN FLAT VENTING ROOL THE WYE, OR COMBO UP PAST THE ? OF HORIZONTAL TRUNK 2) LAV/NOT VENT CORRECTLY, YOU CAN USE A A/A VALVE 3) NEED 2 WAY CLEANOUT MAINTAIN 1/4" PER FT SLOPE ON DRAINAGE PIPE USE A FENCO BAND AT CLAY PIPE TO ABS 4) RAISE ALL REBAR ABOVE GRD 5) DOUBLE FOOTINGS 12" BELOW GRADE
06/18/2004 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*/ 1) SHOWER DRAIN REQUIRES VENT 2) SAN-TEE NOT PERMITTED IN HORIZONTAL DRAINAGE 3) SINK DRAIN MUST CONNECT TO 3" WASTE DOWN STREAM OF TOILET VENT
02/18/2004 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection 0000*/ 1) NO WATER IN PLUMBING FOR TEST