Permit: T03CM01228

Parcel: 133341220

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
11/18/2003 FRAMING Partial Approval IVRS - Inspection 0000* APPROVAL SUBJECT TO ACCEPTANCE IF 1 LAYER BARRACADE WRAP, ALSO POST NEEDS PROPER CLEARANCE ABOVE FINISHED FLOOR.
11/14/2003 FRAMING Partial Approval IVRS - Inspection 0000*
10/29/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NEED HOLD DOWN INFO IN LIEU OF THE MISSED HOLD DOWN STRAPS AND INSTALL. 2) PROPERLY INSTALL CLIPS (FILL IN AND NAIL AT TJI'S) NAILS MISSING. 3) BEARING WALLS NEED TO BE SHOT OR RED HEADED INTO CONCRETE AT BOTTOM PLATE. 4) BLOCK TRUSS AT RATED WALL TO MAINTAIN RATING W/ 5/8" DW. BOTH SIDES AND FIRE STOP ALL PENETRATIONS. 5) STRAP 2ND FLOOR TO 1ST FLOOR FRAMING. 6) FIRE BLOCK AS INDICATED. 7) LIFT POST OFF OF CONCRETE PORCH.
09/12/2003 FRAMING Partial Approval IVRS - Inspection 0000* FIRE BARRIER MUST EXTEND THROUGH DORMER