Permit: T03CM01219

Parcel: 133341220

Inspection Status: Approved

Inspection History: ELECTRIC - CABLE DROP

Date Description Inspector Results Comments
07/07/2004 ELECTRIC - CABLE DROP Approved IVRS - Inspection :*
06/30/2004 ELECTRIC - CABLE DROP Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) DRYWALL SCREW NOT ACCEPTABLE FOR SECURING RISER 2) FINISH GROUNDING RODS AT GAS BONDING #6 CU NOTALLOWED FOR EXPOSED WORK UNLESS PHYSICALLY PROTECTED (THIS IS TYPICAL THROUGHOUT CHANGE THEM ALL OUT OR PYSICALLY PROTECT PER NEC) 4) STRAIGHTEN UP RISER (WORKMANSHYIP AS IS REQUIRED IN ART 110 99 NEC) 5) SECURE LAG TO BOTTOM PLATE NOT 1 X 3 TRIM