Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM01211
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2003 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 06/10/2003 | BUILDING - FINAL | Denied | 1)NEED LETTER FROM LICENSE ELECTRICIAN CONFIRMING ELECTRICAL IS TO CODE. 2) RELOCATE H20 GALV LINES W/ JOINT UNDER SLAB. 3) GAS CODE SHALL BE BEFORE UNION. 4) GAS TEST & PERMIT REQUIRED PRIOR TO RELEASING GAS. | |
| 04/30/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) UNDERGROUNDED 3 WIRE OUTLETS AT LAUNDRY 2) ROMEX (NON METALIC SHEATHED CABLE) EXPOSED AT LAUNDRY 3) ALL WIRING MUST TERMINATE IN APPROVED ELECTRIC BOXES 4) DRYER MUST BE ON A 4 WIRE (3 WIRE GROUNDED) CIRCUITS 5) COMBUSTIBLE MATERIAL WITHIN 6" OF SINGLE WALL FRANKLIN STOVE VENT PIPE 6) PROVIDE FRANLIN STOVE INSTALLATION INSTRUCTIONS 7) APPEARS TO BE NO FOUNDATION UNDER STRUCTURE. PROVIDE PROOF OF FOUNDATION AT ALL BEARING POINTS OF FAMILY ROOM AND PORCH 8) EXPOSE ALL FRAMING FOR FAMILY ROOM WALLS AND CEILING 9) UNSAFE ELECTRICAL DISONNECTS OVERSIZE FUSES FOR WIRING 10) GAS LINES REQUIRE SHUT OFF VALVES BEFORE UNIONS |