Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T03CM01202
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/12/2003 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection 0000*/1) PVC HCS CONNECTION OK. OK TO COVER. | |
08/11/2003 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection 0999*/1) SOIL WATER TEST OK. 2) OK TO BACKFILL TRENCH. 3) MUST RED LINE APPROVED DRAWING SHOWING BLDG DRAIN EXIT OF BLDG. 4) MUST REMOVE C.O. TEE AND SPLICE IN A SOLID CONNECTION TO HCS. CAN NOT USE OR LOCATE A THREADED FITTING IN A CONCEALED LOCATION! SEE SEC. 316.1.2 94 UPC INSTALLATION STANDARDS. 5) DO NOT COVER HCS CONNECTION. |