Permit: T03CM01176

Parcel: 133180080


Addresses:

7078 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
04/22/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*OK FOR C OF O.
04/21/2003 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection 0000*
04/14/2003 MECHANICAL - FINAL Partial Approval IVRS - Inspection 0000*OPEN CEILING TO EXPOSE DUCT WORK FOR INSPECTION. STRAP ALL FLEX DUCT W/MIN 1 1/2" WIDE STRAP EVERY 5'.
2.) PROVIDE AN OUTSIDE AIR INTAKE
3.) PERMANENTLY LABEL A/C UNIT W/ ADDRESS.
4.) REPAIR ELEC. DISCONNECT.
5.) PROVIDE A SERVICE RECEPTACLE ON ROOF WITHIN 25' OF AC UNIT.
6.) PROVIDE A THERMOSTAT.
7.) RE ATTACH CANVAS SUN SHIELD