Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM01170

Parcel: 141301930

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01170

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/16/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/15/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) MISSING 1ST 2ND FLOOR STRAPS 2) AT REAR RUN SHEAR TO TOP CHORD 3) DRIVE ALL HANGER NAILS HOME AT LEDGERS 4) NAIL ROOF DECK TO LEDGER 8D'S EAST WALL 2ND FLOOR 5) SHIM 3 PT GIRDER 6) RED MARKS ON ROOF DECK, TOO BE NAILED 7) 2 UNDER SIZED HEADERS LIVING EAST WALL 3 1/2 X 5 1/2 X 78, 4 3/8 X 3 1/2" GARAGE MAN DOOR