Permit: T03CM01167

Parcel: 106042920

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
06/27/2003 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection 0000*
06/13/2003 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0999*/ 1) THE SERVICE IS ALSO REQUIRED TO HAVE A GAS LINE BOND AND A WATER LINE BOND BOTH ON HOUSE SIDE 2) THE ADDRESS MARKING IS TO BE OF A PERMANENT TYPE, MARKING PEN NOT SUFFICENT WILL FADE OUT
05/22/2003 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0210*
04/17/2003 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection 0210*BE ADVISED:
1.) THE N.E. CODE REQUIRES SINGLE FAMILY RESIDENCE TO HAVE A MINIMUM 100 AMP ELECTRICAL SERVICE LOAD CENTER. THE 40 AMP SWITCH AT THEPOLE IS NO LONGER ACCEPTABLE.
2.) I RECOMMEND YOU INSTALL A 100 AMPERE (OVERHEAD SERVED) METER/MAIN/LOAD CENTER. THE EQUIPMENT SHOULD BE ATTACHED TO THE HOUSE.
PLEASE CONSULT WITH AN ELECTRICAL CONTRACTOR FOR EXPERT DIRECTION ON THE COMPLETE INSTALLATION OF THE ELECTRICAL "SERVICE". THANK YOU.