Permit: T03CM01154

Parcel: 135076100


Addresses:

1990 S MCCONNELL DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01154

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/08/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
04/07/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF BOTTOM EDGE OF OSB ON EAST HIP PLANE 2) STRAP NORTH SIDE OF WINDOW HEADER AT REAR 1ST FLOOR-WHERE OSB IS CUT AND NAIL OSB AT SOUTH SIDE OF SAME WINDOWS