Permit: T03CM01136

Parcel: 133420690

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/26/2003 MECHANICAL - FINAL Approved IVRS - Inspection 0000*
03/19/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*
CONDENSATE TERMINATION NOT INSTALLED CORRECTLY. CORRECT & RECALL FOR INSPECTION.
03/13/2003 MECHANICAL - FINAL Denied IVRS - Inspection 0999*IF YOU ARE GOING TO TERMINATE CONDENSATE INTO THE SEWER VENT YOU MUST USE A TEE ON THE VENT, NOT A HOLE DRILLED INTO THE SIDE OF THE VENT, AND TERMINATE INDIRECTLY WITH AIR GAP INTO THE 90 ELBOW POINTING UPWARD. THE VENT MUST BE MIN 2". THE 90 ELBOW MUST BE LARGER THAN THE DRAIN PIPE.
15 PSI TEST ON GAS LINE IS OK LEFT GAS CARD. RECALL FOR INSPECTION.