Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM01114
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/31/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*ABS TRAP ARM OK 2.) IM CONCERNED THAT STRUCTURAL INTEGRITY ON A BEARING WALL HAS BEEN COMPROMISED, HOWEVER WILL DEFER TO BLDG INSPECTOR. |
|
03/26/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*1.) A SANTEE MAY NOT LAY ON ITS BACK. 2.) A 90 CLEAN OUT EXTENSION SHALL BE MADE THROUGH A WYE BRANCH FITTINGS OR EQUIVLENT SWEEP. 3.) THSI TIME YOU WILL PAY A REINSPECTION FEE. |
|
03/25/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) PLEASE READ NOTE FROM 3/24/03 AND COMPLY. 2.) CONTRACTOR TO PAY RE-INSPECTION FEE. |
|
03/24/2003 | PLUMBING - INTERMEDIATE | Denied | 1.) A CLEAN OUT MAY NOT CONNECT HORIZONTALLY TO A HORIZONTAL DRAIN LINE. | |
03/23/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*PLEASE COMPLY WITH THE NOTES LEFT ON 3/20/03 DO NOT RECALL UNTIL CORRECTIONS HAVE BEEN MADE. | |
03/20/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1.) A TRAP ARM MAY ONLY CHANGE DIRECTION 90 WITHOUT AN ADDITIONAL CLEAN OUT 2.) BOTH SIDES OF NOT STUD MUST BE TIED BACK IN WITH FHA STRAP. |