Permit: T03CM01114

Parcel: 107010300

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/07/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
07/01/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) GFI RECEPTACLE ON NORTH SIDE OF KITCHEN SINK NOT WORKING ALSO WHAT TURN RECEPTACLE ON SOUTH SIDE OF SINK OFF SHOULD ALSO BE PROTECTED BY A GFI ? 2) GFI DOES NOT TRIP ON GROUND TO NETURAL TEST
06/20/2003 ELECTRIC - FINAL Partial Approval IVRS - Inspection 0000*/ 1) PLEASE CORRECT: INSTALL OUTSIDE LITE FIXTURES 2) INSTALL ANTI-TIP DEVICE ON STOVE 3) MARK CIRCUIT INDEX IN POWER PANEL 4) IF POSSIBLE DO A HOT CHECK OF INTERIOR ELECTRICAL PLANT