Permit: T03CM01113

Parcel: 140374300


Addresses:

7040 S DUNNOCK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
05/14/2003 FRAMING Approved IVRS - Inspection 0000*
05/07/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) CLIPS UNDER STAIRS MISSING NAILS AND HANGER MISSING 2) MECHANICAL NOT BLOCKED AT TOP OF STAIRS (RETURN) 3) NAIL PROTECT DRYER VENT UPSTAIRS 4) OUTLET MISSING SOUTH WALL UPSTAIRS BEDROOM 5) NAIL PROTECT PLUMBING UPSTAIRS BATH WITHIN 1 1/2 FROM EDGE OF STUD 6) NAIL PROTECT ELECTRIC IN MASTER BATH 7) NAIL PROTECT ELECTRIC BOTH SIDES OF WINDOW AT SOUTH WEST WALL 8) DOUBLE TOP PLATE AT LIVING ROOM NOT STAGGERED PER CODE COVERED BY CLIPS-REPLACE 9) STOPPED INSPECTION 10) NEXT FAILURE WILL RESULT IN RE-FEES
05/01/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) DWV'S FAILED TEST 2) BEARING STUD IN GARAGE OVER NOTCHED 3) DOUBLE TOP PLATE IN GARAGE REQUIRES ENGINEERING REPAIR 4) DOUBLE TOP PLATE AT GARAGE WEST WALL REQUIRES 16G STRAPS W/ 6 16D NAILS ON EACH SIDE 5) STOPPED INSPECTION