Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM01109

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
05/13/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
05/09/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) 2 NAILS PER WIND BRACE AT PLATES 2) MISSED (STHD) AT EAST SHEAR WALL 3) SHIM FLOOR TRUSS ABOVE GARAGE MAN DOOR AND AT BEDROOM CLOSET FRONT FLOOR BATH LIVING SIDE SHEAR CARRYS DOWN FROM PANELS 5) ADD CRIPPLE AT STAIR BEAM GET NAILED TO FLOOR 7) MAKE SURE DRAG STRUT NAILED 4" ON CENTER STAPLES BOTH TRUSSES 8) GABLE END AND TRUSS CROSS BRACES NAIL TO HORIZONTAL BLOCKS NAILS IN SHEAR NOT WITH DRAWL 9) SISSOR TRUSS CLIPS DON'T USE 8D TECO'S ==10DS