Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/19/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
05/16/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP BOTTOM PLATE AT CONDUIT ON INTERIOR GARAGE WALL 2) REPAIR BLOCKING AT TOP OF INTERIOR GARAGE WALL 3) SHIM PATIO DOOR HEADER AND ALL HEADERS WHERE NEEDED 4) SHIM STRINGERS ON KNEE WALL | |
05/15/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
05/13/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) FHA STRAP BOTTOM PLATE AT CONDUIT ON INTERIOR GARAGE WALL 2) REPAIR BLOCKING AT TOP OF INTERIOR GARAGE WALL 3) FHA STRAP TOP PLATES AT STOVE GAS 4) NAIL OFF FHA STRAPS AT INTERIOR GARAGE WALL 3" ABS AND PLATES (NOT FURRING STRIPS) AT EXTERIOR GARAGE WALL ABS 5) STOPPED INSPECTION AFTER GARAGE 6) MESH NOT DONE AT 2ND FLOOR |