Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM01093
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2003 | PLUMBING - INTERMEDIATE | Approved | ||
| 11/18/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000* | |
| 09/26/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/1) OK TO DRYWALL RM #115. 2) MUST SEE FINAL CONNECTION TO EXTERIOR EXISTING WASTE. | |
| 09/25/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*/1) SOIL WATER TEST IS OK FOR EXISTING REST ROOM #104. 2) OK TO DEYWALL. 3) H.C. RESTROOM, ROOM # 119 IS OK. | |
| 09/17/2003 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection 0000*/1) THIS IS A COMMERCIAL PROJECT. - WHERE ARE YOUR PLUMBING ISOMETRICS? 2) SEE 311.4 - 94 UPC A WASTE PIPE MAY NOT CONNECT TO A VENT. 3) A TRAP ARM MAY NOT CHANGE SIZE. 4) VENTS MUST BE LEVEL OR DRAIN BACK TO FIXTURE SERVED. 5) DRAINAGE PIPING TO BE INSTALLED AT 2%. 6) OK TO POUR #119 HC TOILET RIM. |