Permit: T03CM01075

Parcel: 122181070


Addresses:

3649 E FAIRMOUNT ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/02/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
05/01/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
04/30/2003 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection 0000*
04/28/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) TUB AND W/C NOT PROPERTY VENTED-SANITARY "T" FITTING NOT ALLOWED IN HORIZONTAL DRAIN. HEAL VENT NOT ALLOWED 2) MANY FITTINGS NOT GLUED 3) 10 FOOT WATER TEST REQUIRED ON ALL DWV PER UPC 712.2 4) 3" DRAIN CANNOT BE INSTALLED IN EXISTING 4" SEWER