Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 06/02/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 03/03/2003 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) EXPOSE FOOTING ALONG NORTH WALL TO A DEPTH OF 12" BELOW GRADE ON WALL AND POST FOOTING 2) CLIP LEDGER WITH A34 CLIP AT EXISTING FACIA 3) PLAN CALLS FOR DOUBLE 2 X 6 RAFTERS OR SINGLE 2 X 8 RAFTERS 4) YOU MUST OBTAIN A GAS PERMIT -LINE HAS BEEN RELOCATED 5) EXPOSE ALL FRAME CONNECTIONS AT TOP AND BOTTOM PLATES AND ALL RAFTER CONNECTIONS 6) EXPOSE ALL ELECTRIC WIRING IN ADDITION 7) ELECTRIC OUTLETS WIRED INCORRECTLY-OPEN ALL ELECTRIC BOXES AND REMOVE DEVICES |