Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*CLOSET FLANGE OK 2.) TRAP ARM IS UNCONVENTIONAL, BUT I WILL APPROVE IT. 3.) OK TO COVER ALL AREAS. |
|
03/06/2003 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection 0000*1. ADA REMODEL WATER CLOSET ROUGH OK NEED TO SEE CLOSET FLANGE BEFORE FINAL. 2.) A REDUCING FURNCO ON THE LAVATORY TRAP ARM IS NOT APPROVED. NOTE THE TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM, THE TRAP ARM MAY NOT CHANGE SIZE, AND THE TRAP MAY BE ONLY ONE PIPE SIZE LARGER THAN THE TAIL PIECE TO WHICH IT IS CONNECTED. |