Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/24/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) LOOSING GAS PRESSURE 1 POUND IN 10 MINUTES | |
04/22/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) 4 POUND GAS TEST 2) GARAGE TO HOUSE WALL NAIL OSB TO TRUSS ABOVE CEILING 3) BANG PLATE/TOP 3/4" SMALL CLOSET BEHIND LAUNDRY ALSO DRYER VENT 4) SHIM ALL 3 PT BEARING TRUSSES 5) NEED PERIMETER NAILING SW5 ABOVE CEILING 6) TOOK PLANS WILL ASK PLAN INSPECTOR HOW TO BUILD SHEAR ABOVE CEILING |