Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM00973

Parcel: 141304130

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM00973

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/25/2003 FRAMING Approved IVRS - Inspection 0000*
04/24/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) LOOSING GAS PRESSURE 1 POUND IN 10 MINUTES
04/22/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) 4 POUND GAS TEST 2) GARAGE TO HOUSE WALL NAIL OSB TO TRUSS ABOVE CEILING 3) BANG PLATE/TOP 3/4" SMALL CLOSET BEHIND LAUNDRY ALSO DRYER VENT 4) SHIM ALL 3 PT BEARING TRUSSES 5) NEED PERIMETER NAILING SW5 ABOVE CEILING 6) TOOK PLANS WILL ASK PLAN INSPECTOR HOW TO BUILD SHEAR ABOVE CEILING