Permit: T03CM00970

Parcel: 132100540


Addresses:

3317 S NACO VISTA

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/03/2004 FRAMING Approved IVRS - Inspection 0000*
01/16/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) FIRE BLOCK LAUNDRY SOUTH WALL 2) TWO INCHES CLEARANCE REQUIRED BETWEEN FIRE PLACE CHIMNEY AND STRUCTURAL WOOD 3) TWO JOIST AT FIRE PLACE REQUIRES HANGERS AND DOUBLE JOIST TO SUPPORT HEADER 4) PROVIDE GROUND PIG TAILS FOR ALL SWITCHED 5) PROVIDE A DWV WATER 6) OK TO INSULATE AND DRYWALL ALL BUT FIRE PLACE AND LAUNDRY SOUTH WALL
08/12/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) COMPLETE ALL TRADES AND RECALL
07/11/2003 FRAMING Partial Approval IVRS - Inspection 0000*
07/09/2003 FRAMING Denied IVRS - Inspection 0999*