Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM00955
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/24/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
04/22/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) LOW GAS PRESSURE 6 POUNDS 2) HEAD OFF ABOVE DUCTS KITCHEN 3) SECURE GAS LINE AT FIREPLACE 4) FIRE STOP TO BE AT FLOOR CEILING NOT FLB 5) CRIPPLE STUD UNDER BEAM SUPPORT STAIR 6) FIX BANG PLATE AT TUB 7) 6/SD2 NAIL SHEAR PANELS (2 WALLS) BOTTOM OF SHEAR 2 X 4 TO DOUBLE TOP PLATE 8) #1 SHEAR AT KITCHEN NAIL LADDER BLOCK SHEAR TRANSFER TO TOP PLATE 9) BANG PLATE ROMEX/COMM. WIRE ATTACH SWITCH BOX FOR LIGHTS 2ND FLOOR BED 10) TIGHTEN A.B. THRU OUT |