Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
10/15/2007 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
10/12/2007 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
PROVIDE TEST & TRACER WIRES AND CALL BACK FOR INSPECTION
10/02/2007 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
1. CLEANOUTS ARE OPEN IN THE DIRECTION OF FLOW
2. TWO-WAY CLEANOUT FITTINGS ARE LIMITED TO THE CONNECTION BETWEEN THE BLDG. DRAIN AND THE BLDG. SEWER
3. REMOVE COMBO AT BLDG. CONNECTION AND USE A SWEEP OF 45 DEG. ELL
4. WATER TEST IS FROM LOWEST POINT TO HIGHEST POINT OF SEWER
5. CHECK GRADE AT TWO WAY (PARTIALLY COVERED)