Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM00945
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/02/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
03/31/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) MANY PIECES OF ROOF OSB COVERING ONE BAY ( 2 TRUSSES)-BLOCK AND NAIL 2) BLOCK OSB AT CUT FOR FURNACE FLUE 3) (ROOF OSB) NOT NAILED AT GABLE WALL-BELOW UPPER RIDGE ON NORTHSIDE 4) REAR 2ND FLOOR SHEAR NOT NAILED OFF 5) HAMMER NAILS FLUSH ON REAR GARAGE SHEAR |