Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM00945

Parcel: 135076080


Addresses:

1966 S MCCONNELL DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM00945

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/02/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/31/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) MANY PIECES OF ROOF OSB COVERING ONE BAY ( 2 TRUSSES)-BLOCK AND NAIL 2) BLOCK OSB AT CUT FOR FURNACE FLUE 3) (ROOF OSB) NOT NAILED AT GABLE WALL-BELOW UPPER RIDGE ON NORTHSIDE 4) REAR 2ND FLOOR SHEAR NOT NAILED OFF 5) HAMMER NAILS FLUSH ON REAR GARAGE SHEAR