Permit: T03CM00918

Parcel: 113111010


Addresses:

1701 E SENECA ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T03CM00918

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
09/03/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*/ 1) FLOOR DRAIN-OK, OK TO COVER 2) THIS COMPLETES ROUGH SOIL
08/06/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*
08/05/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) NO ONE ON JOB SITE OR IN TRAILER. / REINSPECTED 2:00 PM. 1" PVC WATER SERVCE TO NEW BATHROOMS OK. TRANSITION FITTINGS OK. OK TO COVER.
07/10/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/ 1) branch piping for restrooms ok, water test one riser to ten feet 2) ok to backfill
07/09/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000*/TRANSITION BANDS- OK. OK TO COVER.
07/07/2003 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection 0000* 6" N/H MAIN THRU BLDG WITH 4" N/H BRANCH ALL WITH HUSKEE BANDS OK. NEED TO SEE TIE-IN CONNECTIONS TO EXSISTING. USE 4 BAND SHIELDED TRANSITION COUPLING. OK TO COVER MAIN AND BRANCH. WILL INSPECT BATHROOM ROUGHS AT A LATER DATE.