Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM00916

Parcel: 110033670

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM00916

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/07/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
06/26/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) HOLDOWNS WRONG LOCATION P3 WALL 2) P3 SHEARWALL NOT NAILED AT 3" ON CENTER EDGES 3) 7/SD3 NOT COMPLIED WITH 4) NON OVERLAPPING DOUBLE TOP PLATES MUST BE STRAPPED SPLICE OVERLAPS MUST STAGGER BY 24"