Permit: T03CM00908

Parcel: 110113620

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T03CM00908

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2003 ELECTRIC - FINAL Approved 1) OK FINAL
06/02/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) AN APPROVED EXTENDER RING IS NEEDED AT COMBUSTIBLE BEARING IN BATHROOM 2) PLEASE TIGHTEN WATER HEATER FLEX FITTINGS AND SECURLY ATTACH DISCONNECT TO WALL 3) RECESSED CANS TO BE ATTACHED TO GRID AND SUPPORTED WITH A SUPPORT WIRE 4) M/C CABLE TO BE SUPPORTED AS PER CODE 300-11-INDEPENDENTLY AND WITHIN 12" 5) PLEASE REVISE PLANS FOR LIGHTING 6) BOND JUNTION BOXES 250-148 7) TIGHTEN LOOSE CHORD CONNECTORS